CYBERPOWER OLS3000ERT2Ua
350 190 Ft
Product description
The CyberPower OLS1000ERT2UA is a high-performance UPS with an online double-conversion topology that provides smooth pure sine wave power for critical devices such as NAS and servers, DVR/surveillance systems, transportation and infrastructure, and emergency systems. It is usually integrated into the back office, server room and data center environment.

- Smart App support
- Online double conversion UPS topology
- ECO mode
- Generator compatible
- Overcharge protection
- Zero transition time
- Intelligent Battery Management (SBM)
- Extended Battery Module (EBM)
- Surge and spike protection
- EMI and RFI filtering
- Telephone/fax/modem/DSL/network protection
- LCD status indicator
- Emergency Power Off (EPO) port
- PowerPanel Management software
- SNMP/HTTP remote monitoring capability (optional)
- Rack/tower convertible configurations

Technical data
- Phase: Single phase
- UPS topology: Online double conversion
- Energy-saving technology: Online ECO mode, efficiency > 95%
- Active PFC compatibility
- Generator compatibility
- Nominal input voltage: 230 V AC ± 10%
- Input voltage range: 190 V ~ 300 V AC
- Adjustable voltage range: 0% ~ 50% load: 110V ~ 300V AC; 0% ~ 60% load: 140V ~ 300V AC; 0% ~ 80% load: 160V ~ 300V AC; 0% ~ 100% load: 190V ~ 300V AC
- Input frequency: 50 Hz ± 10%, 60 Hz ± 10%
- Input frequency detection: automatic detection
- Rated input current: 13 A
- Input power factor: 0.98
- Input connector type: IEC C20
- Detachable power cable plug type: Schuko
- Network cable length: 1.8 meters
- Capacity: 3000 VA/2700 W
- Battery waveform: pure sine wave
- Battery voltage: 208 V AC ± 1%, 220 V AC ± 1%, 230 V AC ± 1%, 240 V AC ± 1%
- Output voltage setting: configurable
- Battery frequency: 50 Hz ± 0.5%, 60 Hz ± 0.5%
- Output frequency setting: configurable
- Power factor: 0.9
- ECO mode voltage tolerance: ± 15%
- Overload protection: internal current limitation, circuit breaker, fuse
- Overload protection: Line mode: 110% ~ 120% load for 1 minute, >120% load immediately; Battery mode: 110% ~ 120% load for 10 seconds, >120% load immediately; Bypass mode: >130% load immediately
- Crest factor: 3:1
- Harmonic distortion: Linear load: THD < 3%, Non-linear load: THD < 5%
- Internal bypass: automatic bypass, manual bypass
- 2 IEC C19 outputs
- 8 IEC C13 outputs
- Battery and overvoltage protected output: 9 pieces
- Typical transition time: 0 ms
- Bridging time: Half load: 14 minutes, Full load: 4 minutes
- Typical charging time: 5 hours
- Maximum charging current: 1 A
- Start on battery
- Intelligent battery management
- Battery replaceable by the user and during operation
- Battery type: Sealed lead acid
- Replacement battery pack: 1 RBP0070
- Battery quantity (all replacement battery packs): 6 pieces
- Battery voltage (all replacement battery packs): 72 V
- Battery capacity: 12 V, 9 Ah
- Extended battery module: BPSE72V45ART2U
- Maximum extended battery module quantity: 3 pieces
- Surge suppression: 440 J
- EMI/RFI filtering
- Telephone/network protection, RJ11/RJ45 combined: 1 input, 1 output
- LCD panel
- LCD information display: Operation type, power supply status, battery status, load status, error and warning, other information, event and log
- LCD setting and control: Mode setting, alarm setting, input and output, battery setting
- HID compatible USB port: 1 piece
- Serial port: RS232
- Emergency Power Off (EPO) port
- Sound signals: Battery mode, low battery, overload, overcharge, overheating, UPS error, battery replacement
- Management cable: 2 power cables, 1 USB cable, 1 phone cable
- Energy management software: PowerPanel Business
- SNMP/HTTP remote monitoring: optional RMCARD205
- Design: Rack/tower
- Housing structure: Metal
- Color: black
- Rack mountable rail
- Size: 438mm x 88mm x 610mm
- Weight: 27.5 kg
- Installed rack height: 2U
- Operating temperature: 0°C ~ 40°C
- Operating humidity: 20% ~ 90%
- Storage temperature: 20°C ~ +50°C
- Storage humidity: 10% ~ 90%
- Audible noise 1.5 meters from the surface of the unit: 45 dBA